2001 Ford E-350 Recalls

Recalls on record Updated July 2026

The 2001 Ford E-350 has 4 NHTSA recall campaigns affecting an estimated 8,476,000 vehicles. Recall repairs are always free at any authorized dealer. Owners have filed 59 complaints with NHTSA, most often about the engine and engine cooling. Last updated July 5, 2026.

Recall campaigns

VEHICLE SPEED CONTROL 09V399000 2009-10-13 4,500,000 affected
Defect

FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED…

Consequence

A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy

FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27,…

VEHICLE SPEED CONTROL 08V051000 2008-02-04 225,000 affected
Defect

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A…

Consequence

AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy

DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

VEHICLE SPEED CONTROL 07V336000 2007-08-03 3,600,000 affected
Defect

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence

THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy

DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL…

FUEL SYSTEM, GASOLINE 01V114000 2001-04-05 151,000 affected
Defect

VEHICLE DESCRIPTION: ON CERTAIN VANS WITH AMBULANCE PREP PACKAGES OR OTHER SEVERE-DUTY APPLICATIONS INVOLVING OPERATION AT OR NEAR THE GROSS VEHICLE WEIGHT WITH FREQUENT TWISTING OF THE VEHICLE BODY, SUCH AS OFF-ROAD, ROUGH ROAD OR SPEED BUMP EVENTS, THE 35 GALLON MID-SHIP FUEL TANK COULD DEVELOP A CRACK WHERE IT…

Consequence

FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A FIRE.

Remedy

DEALERS WILL INSPECT THE FUEL TANK AND, IF CRACKED, WILL REPLACE THE TANK. INSULATOR PADS WILL BE INSTALLED ON ALL VEHICLES TO REDUCE THE STRESS LEVELS IN THE FUEL TANK. OWNER NOTIFICATION BEGAN APRIL 19, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE…

Complaints by component

ENGINE AND ENGINE COOLING
9
2fires
ENGINE AND ENGINE COOLING:ENGINE
4
FUEL SYSTEM, DIESEL
4
POWER TRAIN:AUTOMATIC TRANSMISSION
4
ENGINE
3
TIRES
3
1fires
ELECTRICAL SYSTEM
2
1fires
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE
2
FUEL SYSTEM, DIESEL:STORAGE:TANK ASSEMBLY
2
SEAT BELTS:FRONT:BUCKLE ASSEMBLY
2
Total complaints59

What owners report

Verbatim reports filed with NHTSA, lightly edited for readability and with personal information removed.

“Spark plug - I'm really shocked this hasn't been recalled! Purchased this 2001 ford e-350 from the original owner who was a mechanic and kept all service records of this vehicle. It is in excellent condition. Had the van serviced and looked over before taking it on a longer trip. At 2 am and only…”

ENGINE · reported 2020-09-07

“The driver's side seat belt randomly comes unlatched. This has happened before this date and happens multiple times each time it is driven. It does not matter if the vehicle is in motion or not. It has happened sitting still in the driveway and at highway speeds. This is a trw 33012760 part.”

SEAT BELTS · reported 2018-05-08

“My 2001 ford e350 super duty van blew out a spark plug while driving 40 mph and cost me $900 for dealership to repair....with only 117,000 miles on it. Ford needs to do a recall on this. *tr”

ENGINE · reported 2016-10-14

“Spark plug was ejected from engine. No advanced warning or unusual sounds of any kind. Engine had been running perfectly and reliably up until this event.”

ENGINE · reported 2015-09-13

“While driving vehicle started running rough/missing lost engine power. Had to have the vehicle towed home replaced the fuel filter and pump. Still had problems. Towed to the dealer who finally advised fuel tank laminate was flaking. Found 4 other complaints on this site for the same problem.…”

FUEL SYSTEM, GASOLINE · reported 2012-04-21

“While driving vehicle started running rough/missing lost engine power. Had to have the vehicle towed home replaced the fuel filter and pump. Still had problems. Towed to the dealer who finally advised fuel tank laminate was flaking. Found 4 other complaints on this site for the same problem.…”

ENGINE AND ENGINE COOLING · reported 2012-04-21

“Spark plug blow out of 5.4l engine causing gas fumes in passenger area. *tr”

ENGINE AND ENGINE COOLING · reported 2011-12-08

“2001 ford e-250. Consumer states leak in fill hose *tgw the consumer stated the fill hose had to be replaced twice, because it leaked when re-fueling. *jb”

FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS · reported 2011-09-01

Defect investigations

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation EA02018 Opened 2002-08-19 · closed 2003-08-22

RAPID TIRE DEFLATION

THIS INVESTIGATION WAS OPENED ON CERTAIN FORD PICKUP TRUCKS AND VANS TO EVALUATE THE EFFECTS OF A VALVE STEM EJECTION (WITH RAPID AIR LOSS) AND A SLOW LEAKING VALVE STEM ON VEHICLE HANDING.DURING THE INVESTIGATION, ODI EVALUATED OVER 1,100 COMPLAINTS AND WARRANTY CLAIMS, CONDUCTED VEHICLE DYNAMIC TESTING ON A SUBJECT…

Investigation EA02018 Opened 2002-08-19 · closed 2003-08-22

RAPID TIRE DEFLATION

THIS INVESTIGATION WAS OPENED ON CERTAIN FORD PICKUP TRUCKS AND VANS TO EVALUATE THE EFFECTS OF A VALVE STEM EJECTION (WITH RAPID AIR LOSS) AND A SLOW LEAKING VALVE STEM ON VEHICLE HANDING.DURING THE INVESTIGATION, ODI EVALUATED OVER 1,100 COMPLAINTS AND WARRANTY CLAIMS, CONDUCTED VEHICLE DYNAMIC TESTING ON A SUBJECT…

Investigation EA10003 Opened 2010-04-13 · closed 2012-03-05

HVAC Switch Failures

This investigation was opened based on one complaint and reports from four transportation fleets alleging 182 blower motor control switch failures.ODI was concerned that these melting and burning switches could lead to an open flame that could spread throughout the vehicle.After a comprehensive review of all data…

Investigation PE09055 Opened 2009-12-07 · closed 2010-04-21

HVAC Switch Failures

ODI has received 1 complaint and reports from 4 transportation fleets alleging 182 switch failures.Each fleet operates mini buses built on a Ford E350 or E450 cutaway chassis.The OEM HVAC blower switches have melted, smoked, burned or experienced open flame and become inoperable on vehicles in each fleet.Some drivers…

Sources & methodology

Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 2001 Ford E-350 as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.